  • ICT-CTKC Puncture Current Transformer (With Temperature)
    ICT-CTKC Puncture Current Transformer (With Temperature)
    Puncture current transformer is installed online without power failure, with built-in current transformer, electric needle, temperature sensor, diversified integrated design concept and convenient installation. It’s mainly used in power transformation and installation projects. All manual operation places are insulators, so the installation is safe, convenient and simple. When the puncture current transformer is installed, the measure line passed through the middle hole, and the current signal is output after passing through the transformer, which is converted into the required voltage signal by the sampling resistance and output as lead.
    Quick View
  • Open-close Type Current Transformer
    ICT-CTK Open-close Type Rectangular Residual Current Transformer
    Rectangular open close residual current transformer is mainly used in cable circuit environment. It has simple structure, small volume and flexible application. According to specifications of the cable used in the main circuit, there are various through hole diameters. The through hole diameter of this series of product ranges from 110mm to 400mm, and the main circuit current includes 63A to 2000A. This series of products can meet the technical requirements of0.1level, 0.2 level, 0.5 level and 1 level and other difference precision. At the same time, it can also meet the strict requirements of the new national standard for the balance characteristics. The unbalanced current output value can also be better than 30mA, 10mA, 5mA, or even 3mA, greatly reducing the false alarm caused by the magnetic field interference of the main circuit current, providing sufficient guarantee for the reliability of the equipment. Excellent and advanced production process. This series of products meet the requirements of GB-14287.2-2005 and GB14287.2-2014.  
    Quick View
  • Circular Residual Current Transformer
    ICT-CTK Open-Close Type Circular Residual Current Transformer
    Circular switching residual current transformer is mainly used in cable circuit environment. It has simple structure, small volume and flexible application. According to the specifications of cable used in the main circuit,it has a variety of through hole diameter. The through hole diameter of this series of product is from 30mm to 200mm, and the main circuit current includes 63A ~ 2000A. The series of products can meet the technical requirements of different precision such as 0.2, 0.5 and 1. At the same time, it can also meet the strict requirements of the new national standard for the balance characteristics. The unbalanced current output value can also be better than 30mA, 10mA, 5mA, or even 3mA, greatly reducing the false alarm caused by the interference of the current and magnetic field of the main circuit, and provides sufficient guarantee for the reliability of the equipment. Excellent and advanced production process. This series of products meet the requirements of GB-14287.2-2005 and GB14287.2-2014.
    Quick View
  • ICT-CTY2 Circular Combined Residual Current Transformer
    ICT-CTY2 Circular Combined Residual Current Transformer
    Circular combined residual current transformer is mainly used in cable circuit environment. It has simple structure, small volume and flexible application. According to the specifications of cable used in the main circuit,it has a variety of through hole diameter. The through hole diameter of this series of product is from 45mm to 100mm, and the main circuit current includes 63A ~ 2000A. The series of products can meet the technical requirements of different precision such as 0.2, 0.5 and 1. At the same time, it can also meet the strict requirements of the new national standard for the balance characteristics. The unbalanced current output value can also be better than 30mA, 10mA, 5mA, even 3mA, which greatly reduces the false alarm caused by the interference of the current and magnetic field of the main circuit, and provides sufficient guarantee for the reliability of the equipment. Excellent and advanced production process. This series of products meet the requirements of GB-14287.2-2005 and GB14287.2-2014.
    Quick View
  • Rectangular Combined Residual Current Transformer
    ICT-CTYF1 Rectangular Combined Residual Current Transformer
    Rectangular combined residual current transformer is mainly used in cable circuit environment. It has simple structure, small volume and flexible application. According to specifications of the cable used in the main circuit, there are various through hole diameters. The through hole diameter of this series of product ranges from 100mm to 490mm, and the main circuit current includes 63A to 2000A. This series of products can meet the technical requirements of 0.2 level, 0.5 level and 1 level and other difference precision. At the same time, it can also meet the strict requirements of the new national standard for the balance characteristics. The unbalanced current output value can also be better than 30mA, 10mA, 5mA, or even 3mA, greatly reducing the false alarm caused by the magnetic field interference of the main circuit current, providing sufficient guarantee for the reliability of the equipment. Excellent and advanced production process. This series of products meet the requirements of GB-14287.2-2005 and GB14287.2-2014.  
    Quick View
  • ICT-CTY Combined Residual Current Transformer
    ICT-CTY Combined Residual Current Transformer
    The Circular combined residual current transformer is mainly used in cable circuit environment. It has simple structure, small volume and flexible application. According to the specifications of the cable used in the main circuit, there are a variety of through hole diameters. The through hole diameter of this series of products ranges from 45mm to 100mm, and the main circuit current includes 63A ~ 2000A. The series of products can meet the technical requirements of grade 0.2, grade 0.5, grade 1 and other different precision. At the same time, it can also meet the strict requirements of the new national standard for the balance characteristics. The unbalanced current output value can also be better than 30mA, 10mA, 5mA, even 3mA, greatly reducing the false alarm caused by the magnetic field of the main circuit current, providing sufficient guarantee for the reliability of the equipment. Excellent and advanced production process. This series of products meet the requirements of GB-14287.2-2005 and GB14287.2-2014.
    Quick View
  • Circular Residual Current Transformer
    ICT-CT11 Series Circular Residual Current Transformer
    Circular through type current transformer is mainly used in cable circuit environment. It has simple structure, small volume and flexible application. According to the cable specifications of cable used in the main circuit, there are a variety of through hole diameters. The through hole diameter of this series of products ranges from 30mm to 200mm, and the main circuit current includes 63A ~ 2000A. The series of products can meet the technical requirements of 0.2 level, 05level, 1level and other different precision. At the same time, it can also meet the strict requirements of the new national standard for the balance characteristics. The unbalanced current output value can also be better than 30mA, 10mA, 5mA, even 3mA, greatly reducing the false alarm caused by the magnetic field of the main circuit current, providing sufficient guarantee for the reliability of the equipment. Excellent and advanced production process. This series of products meet the requirements of GB-14287.2-2005 and GB14287.2-2014.  
    Quick View
  • Circular Residual Current Transformer
    ICT-Y Series Circular Residual Current Transformer
    The circular through core current transformer is mainly used in the  cable circuit environment, which has simple structure, small volume and flexible application. According to the cable specifications used in the main circuit, there are many kinds of hole diameter corresponding to the core penetration. The diameter of the pierce hole of this series of product is from 25mm to 200mm, and the current of the main circuit includes 63A ~ 2000A. The series of products can meet the technical requirements of different precision such as 0.2, 0.5 and 1. At the same time, it can also meet the strict requirements of the new national standard for the balance characteristics. The unbalanced current output value can also be better than 30mA, 10mA, 5mA, even 3mA, which greatly reduces the false alarm caused by the interference of the current and magnetic field of the main circuit, and provides sufficient guarantee for the reliability of the equipment. Excellent and advanced production process. This series of products meet the requirements of GB-14287.2-2005 and GB14287.2-2014.
    Quick View
  • ICT-ZLCT DC Leakage Current Isolation Transformer
    ICT-ZLCT DC Leakage Current Isolation Transformer
    The product is perforated input single-channel DC leakage current isolated transmitter. The measured DC current signal is isolated by a high-precision isolation device, and the output is linear 0~5V,0~10V, 0~20mA,4~20mA and other standard signals. It is widely used in power supply equipment, power grid monitoring, industrial control monitoring system, railway signal system and other industries.
    Quick View
  • Open-Close Type Outdoor Waterproof Transformer
    ICT-CTHW1 Open-Close Type Outdoor Waterproof Transformer
    Open-close outdoor waterproof transformer, the biggest feature of this series of transformers is the waterproof function, which can be used outdoors. Its section port is surrounded by rubber pads to prevent rain from entering. Of course, most so-called waterproof transformers on the market use rubber pads as a means, but there are also limitations in using this means for waterproofing. Because it is impossible to guarantee the water proof of the transformer itself ,our company adopts the technology of transformer forming once, that is, the transformer is directly made into a solid in the mold, and the plastic is wrapped around the whole body without any gap. Meanwhile, waterproof terminals and sheath lines are used in the secondary side leads to ensure that no rain can enter the transformer body. Our company transformer waterproof grade has reached IP67/IP65. This product meets part of the standard GB20840.1.2 . 