Three Phase Current Transformer

  • ICT-LSY3-10/130  Three Phase Integrated Current Transformer
    ICT-LSY3-10/130 Three Phase Integrated Current Transformer
    LSY3-10/130 three-phase integrated current transformer is suitable to be installed on the three-phase bushing of ring network switch cabinet and main column. It is used for the measurement and protection of three-phase current and zero sequence current, and can also be used for the measurement and protection of zero sequence current of multiple cables circuits. The iron core and secondary winding of this series of current transformers are vacuum-cast with high quality epoxy resin in a flame-retardant plastic housing, which is moisture-proof, stable and maintenance-free.  
    Quick View
  • ICT-LSY3-10/127  Three Phase Integrated Current Transformer
    ICT-LSY3-10/127 Three Phase Integrated Current Transformer
    LSY3-10/127 three-phase integrated current transformer is suitable to be installed on the three-phase bushing of ring network switch cabinet and main column. It is used for the measurement and protection of three-phase current and zero sequence current, and can also be used for the measurement and protection of zero sequence current of multiple cables circuits. The iron core and secondary winding of this series of current transformers are vacuum-cast with high quality epoxy resin in a flame-retardant plastic housing, which is moisture-proof, stable and maintenance-free.
    Quick View
  • ICT-CT107 Three Phase Current Transformer
    ICT-CT107 Three Phase Current Transformer
    CT107 three-phase integrated current transformer is suitable to be installed on the three-phase bushing of ring network switch cabinet and main column switch, which is used for the measurement and protection of three-phase current and zero sequence current, and can also be used for the measurement and protection of zero sequence current of multiple cables  circuits. The iron core and secondary winding of this series of current transformers are vacuum-cast with high quality epoxy resin in a flame-retardant plastic housing, which is moisture-proof, stable and maintenance-free.  
    Quick View
  • ICT-Y3 Circular Three-phase Current Transformer
    ICT-Y3 Circular Three-phase Current Transformer
    Round three-phase current transformer designed for collecting current signals. The secondary current is mA level and must be used in the core threading mode, which is designed strictly in accordance with the standard NSX and NXM MCCB routing dimensions. This series of products has a wide measuring range ,rated primary current range 1A~800A rated secondary current range: 20mA ~1A,excellent advanced production process. To ensure its accuracy level, reliability and other technical requirements, this series of products meet the requirements of GB 28184-2011, and GB14287.2-2014.
    Quick View
  • ICT-CTS6-2 Three-phase Digital Current Transformer
    ICT-CTS6-2 Three-phase Digital Current Transformer
    Three-phase digital current transformer designed for collecting current signals. The secondary current is mA level and must be used in the core threading mode, which is designed strictly in accordance with the standard NSX and NXM MCCB routing dimensions. This series of products has a wide measuring range ,rated primary current range 0A~800A rated secondary current range: 20mA ~5A,excellent advanced production process. To ensure its accuracy level, reliability and other technical requirements, this series of products meet the requirements of GB 28184-2011, GB/T20840.1.2 and GB14287.2-2014.
    Quick View
  • high precision Three-phase Digital Current Transformer
    ICT-CTS6 Three-phase Digital Current Transformer
    Three-phase digital current transformer designed for collecting current signals. The secondary current is mA level and must be used in the core threading mode, which is designed strictly in accordance with the standard NSX and NXM MCCB routing dimensions. This series of products has a wide measuring range ,rated primary current range 0A~800A rated secondary current range: 20mA ~5A,excellent advanced production process. To ensure its accuracy level, reliability and other technical requirements, this series of products meet the requirements of GB 28184-2011, GB/T20840.1.2 and GB14287.2-2014.
    Quick View
  • ICT-CT9 Three-phase Current Transformer
    ICT-CT9 Three-phase Current Transformer
    Three-phase current transformer, designed for collecting current signals. The secondary current is mA level and must be used in the core threading mode, which is designed strictly in accordance with the standard NSX and NXM MCCB routing dimensions. This series of products has a wide measuring range ,rated primary current range 5A~6000A rated secondary current range: 20mA ~5A,excellent advanced production process. To ensure its accuracy level, reliability and other technical requirements, this series of products meet the requirements of GB 28184-2011, GB/T20840.1.2 and GB14287.2-2014.
    Quick View
  • Three-phase Current Transformer
    ICT-CT5 Three-phase Current Transformer
    Three-phase current transformer, designed for collecting current signals. The secondary current is mA level and must be used in the core threading mode, which is designed strictly in accordance with the standard NSX and NXM MCCB routing dimensions. This series of products has a wide measuring range ,rated primary current range 1A~1000A rated secondary current range: 20mA ~5A,excellent advanced production process. To ensure its accuracy level, reliability and other technical requirements, this series of products meet the requirements of GB 28184-2011, GB/T20840.1.2 and GB14287.2-2014.
    Quick View
  • ICT-CT3 Three-phase Current Transformer
    ICT-CT3 Three-phase Current Transformer
    Three-phase current transformer, designed for collecting current signals. The secondary current is mA level and must be used in the core threading mode, which is designed strictly in accordance with the standard NSX and NXM MCCB routing dimensions. This series of products has a wide measuring range ,rated primary current range 1A~800A rated secondary current range: 20mA ~1A,excellent advanced production process. To ensure its accuracy level, reliability and other technical requirements, this series of products meet the requirements of GB 28184-2011, GB/T20840.1.2 and GB14287.2-2014.
    Quick View
  • ICT-CT46 Three-phase Intelligent Digital Transformer
    ICT-CT46 Three-phase Intelligent Digital Transformer
    Three-phase intelligent digital transformer, designed for collecting current signals. The secondary current is mA level and must be used in the core threading mode, which is designed strictly in accordance with the standard NSX and NXM MCCB routing dimensions. This series of products has a wide measuring range ,rated primary current range 1A~800A rated secondary current range: 20mA ~1A,excellent advanced production process. To ensure its accuracy level, reliability and other technical requirements, this series of products meet the requirements of GB 28184-2011,GB/T20840.1.2 and GB14287.2-2014.  