SEN-CTLSY Cable Type Puncture Roche Coil Transformer

Flexible Roche coil current sensor is used to measure AC Current, especially high current. Because of its flexible characteristics, it can be used to measure the conductor current with large size (such as conductor diameter ≥3M) or irregular shape or narrow space between conductor ( for example, when the traditional clamp current probe can not measure, the flexible Rogowski coil current sensor can be used to measure conveniently.) The former is plug-in type, which is used for temporary measurement of portable instrument or current, and for on-line long-time measurement of current. It is easy to install without damaging the conductor. It can be equipped with puncture device, temperature sensor device. Suitable for all kinds of busbar installation.

Inquiry Now

Technical Parameter

  • Maximum withstand voltage: 0.66KV (Customized for special requirements)
  • Rated primary current: 0A ~300KA
  • Rated secondary output: with integral: 4V, 1A (A.C) or 4~20mA (DC), No integral: 100mV/KA, 50mV/kV
  • Accuracy:1%
  • Noted: Other specifications can be customized according to the specification requirements of customers.

 

Performance Index

Electrical Parameters

100% ~100% Accuracy

5% ( Without Integrator); 1%(  With Integrator, 45~65Hz)

Phase Error

W±1° 45~65Hz), W±10° (20Khz)

100% ~100% Linearity

0.50%

Integrator Power Supply

7~30VDC

Response Bandwidth

1Hz- 1MHz

Coil Section Diameter

W7.5, W10, W12mm or Customized

Coil Length

W2M or Customized

Use Altitude

W2000M

Protection Level

IP65

Texture of Material

Silicon Rubber

Secondary Lead

Shielded Wire, Length Customized

Compressive Strength

2KVAC /min

Insulation Resistance

DC500V /100MQ

Scope of Puncture

10V~380V

Temperature Sensor Range

10K~100K

 

Outline and Installation Dimensions

Model & Specification

Rated Input

Rated Output

Accuracy
Class

Dimensions (mm)

(A)

(mA/V)

Φ1

Φ2

A

B

CTLSY

0~300KA

0~100mV
4~20mADC
0~20mADC
0~5VDC
0~10VDC
0~5V
RS485

0.5
1.0
1.5
2.0

30
40
80
100
150
200
300
400

7.5
10
12

41.5

55.7

 